Skip to content
ScienceQuest

Mobitz type 2 AV block on an EKG

A 6-second lead II strip of second-degree AV block, Mobitz type 2, on ECG (EKG) paper with 4:3 conduction, drawn by the ECG rhythm simulator’s model, with the guideline criteria and the pause across the dropped beat.

Lead II, 6 seconds at 25 mm/s and 10 mm/mV: each small square is 0.04 s and 0.1 mV, each large square 0.2 s and 0.5 mV, and the step at the left is the 1 mV calibration pulse. Filled triangles mark P waves that reached the ventricles, open triangles those that did not.

What does Mobitz type 2 look like on an EKG?

Every conducted beat has the same PR interval, before and after a P wave that suddenly fails to reach the ventricles, with no lengthening of the PR to warn of it. The block is usually below the AV node, in the His-Purkinje system, often with a wide QRS, and it can progress to complete heart block.

Defining criteria

Rates and intervals on this strip

Rates and intervals of the Mobitz type 2 strip above, from the simulator’s model
Ventricular rate 56.25 bpm
Atrial rate 75 per minute
P waves conducted 3 of every 4
PR interval 160 ms
QRS duration 80 ms
QT interval 413 ms
QTc (Bazett) 400 ms
RR interval 800 to 1600 ms
Regularity Regularly irregular
Six-second count 6 QRS × 10 = 60 bpm

Measuring the group

The PR is 160 ms in every conducted beat, so the conducted beats come every 800 ms, the PP interval. The dropped P wave leaves a gap of exactly 2 × 800 = 1600 ms, and 3 QRS complexes for every 4 P waves give 75 × 3 / 4 = 56.25 beats per minute.

The 2018 guideline recommends a permanent pacemaker for acquired Mobitz type 2 with no reversible or physiologic cause, whether or not it causes symptoms. Widen the QRS to 120 ms or more in the simulator to see the wide QRS it most often comes with.

Settings the simulator allows for this rhythm

Each rhythm limits its settings to the values its definition allows, so the simulator can never draw it as something else.

Settings the ECG simulator allows for Mobitz type 2, and the value the strip above uses
Setting Allowed This strip
Sinus rate 40 to 99 bpm 75 bpm
PR interval 120 to 280 ms 160 ms
QRS duration 60 to 160 ms 80 ms
Conduction ratio 3:2, 4:3, 5:4 or 6:5 4:3

Telling it apart

Sources

  1. Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay. Circulation. 2019;140(8):e382-e482. doi:10.1161/CIR.0000000000000628
  2. Kligfield P, Gettes LS, Bailey JJ, et al. Recommendations for the Standardization and Interpretation of the Electrocardiogram, part I. Circulation. 2007;115:1306-1324. doi:10.1161/CIRCULATIONAHA.106.180200
  3. McSharry PE, Clifford GD, Tarassenko L, Smith LA. A dynamical model for generating synthetic electrocardiogram signals. IEEE Transactions on Biomedical Engineering. 2003;50(3):289-294. doi:10.1109/TBME.2003.808805
  4. Bazett HC. An analysis of the time-relations of electrocardiograms. Heart. 1920;7:353-370.

The values are facts and free to use; this page’s selection and presentation are © 2026 ScienceQuest.

See also