Third-degree (complete) heart block on an EKG
A 6-second lead II strip of third-degree AV block, complete heart block, on ECG (EKG) paper, drawn by the ECG rhythm simulator’s model with P waves at 75 per minute and a junctional escape at 44, with the guideline criterion and every P to QRS gap measured.
How do you recognize complete heart block on an EKG?
The P waves and QRS complexes each keep their own regular rate with no link between them, so the gap from P wave to QRS changes every beat and the P waves outnumber the QRS complexes. An escape rhythm drives the ventricles: junctional at 40 to 60 per minute, or ventricular at 20 to 40.
Defining criteria
- No evidence of conduction from the atria to the ventricles. (Kusumoto et al. 2018)
- In the model a junctional escape keeps the QRS width set for the rhythm, 80 ms here, and a ventricular escape has a QRS of 140 ms and a T wave pointing the other way. (simulator model)
- The simulator holds the atrial rate at 65 to 110, above the fastest escape rate, so the P waves always outpace the QRS complexes. (simulator model)
Rates and intervals on this strip
| Ventricular rate | 44 bpm |
|---|---|
| Atrial rate | 75 per minute |
| P waves conducted | None |
| PR interval | None, no P wave is conducted |
| QRS duration | 80 ms |
| QT interval | 467 ms |
| QTc (Bazett) | 400 ms |
| RR interval | 1364 ms |
| Regularity | Regular |
| Six-second count | 4 QRS × 10 = 40 bpm |
Marching out the P waves
From the last P wave to each QRS on the strip the gap is 420, 184, 747 and 511 ms, never the same twice, which is what no conduction looks like. The P waves keep coming every 800 ms straight through the beats: 3 of the 8 on this strip start inside a QRS complex or its T wave, where only calipers set from the visible ones find them.
The escape rate is 44 rather than a round 45 for a reason. 75 and 45 share a factor, so with those rates the pattern would repeat every 4 seconds and the P waves would land at only 5 points of the escape cycle, which can look like a fixed link between them. 75 and 44 share none, so the pattern takes 60 seconds to repeat and the P waves drift through every part of the cycle.
The 2018 guideline recommends a permanent pacemaker for acquired third-degree AV block with no reversible or physiologic cause, whether or not it causes symptoms.
Settings the simulator allows for this rhythm
Each rhythm limits its settings to the values its definition allows, so the simulator can never draw it as something else.
| Setting | Allowed | This strip |
|---|---|---|
| Atrial (sinus) rate | 65 to 110 bpm | 75 bpm |
| Escape rate, junctional | 40 to 60 bpm | 44 bpm |
| QRS duration | 60 to 160 ms | 80 ms |
| Escape rate, ventricular | 20 to 40 bpm | Not drawn |
| Escape rhythm | Junctional or ventricular | Junctional |
Telling it apart
- In 2:1 AV block every conducted beat keeps the same PR; in complete heart block the gap changes from beat to beat.
- Two or more P waves in a row not conducted, with conduction at other times, is advanced or high-grade AV block, which the guideline defines separately and the simulator does not draw.
- A slow rhythm with one P wave before each QRS at a fixed PR is sinus bradycardia.
Sources
- Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay. Circulation. 2019;140(8):e382-e482. doi:10.1161/CIR.0000000000000628
- Kligfield P, Gettes LS, Bailey JJ, et al. Recommendations for the Standardization and Interpretation of the Electrocardiogram, part I. Circulation. 2007;115:1306-1324. doi:10.1161/CIRCULATIONAHA.106.180200
- McSharry PE, Clifford GD, Tarassenko L, Smith LA. A dynamical model for generating synthetic electrocardiogram signals. IEEE Transactions on Biomedical Engineering. 2003;50(3):289-294. doi:10.1109/TBME.2003.808805
- Bazett HC. An analysis of the time-relations of electrocardiograms. Heart. 1920;7:353-370.